The DewTrace is a high precision bench top laboratory standard dewfrost point hygrometer capable of measuring very low frost points using the primary method chilled mirror measurement technique. Michells Chilled Mirror Dew Point Meters are precision instruments for critical measurement and control applications.
045 to 100 RH Accuracy of 027F Single two stage and harsh environment sensor options Dual 4-20mA outputs.
Chilled mirror dew point method. Michells Chilled Mirror Dew Point Meters are precision instruments for critical measurement and control applications. The fundamental nature of this method means that Chilled Mirror instruments can be used as either extremely reliable and stable field instruments or as laboratory reference standards for the calibration of other devices. Chilled mirrors are used where accuracy typically -015 C is paramount.
Also Chilled mirrors work well due to their ruggedness simple maintenance and ability to accurately measure sample gasses remotely from process ie. Ovens dryers furnaces etc. Dew points above ambient can be measured by heating the chilled mirror and associated components.
Chilled mirrors can be and are. When a certain volume of gas is cooled uniformly under a constant pressure the partial pressure of the gas and the moisture in the gas remains unchanged until the moisture in the gas reaches a saturated state and the temperature in this state is the dew point of the gas. Usually the mirror surface and its accessories are installed in the measurement chamber through which the gas flows and the dew point of the gas is determined by measuring the temperature of the mirror surface when the.
The Basic Protocol describes the determination of water activity of a product using a chilled mirror dew-point water activity meter. Dew point is a primary measurement of vapor pressure that has been in use for decades Harris 1995. Dew-point instruments are accurate fast simple to use and precise Richard and Labuza 1990.
Snavely et al 1990. Roa and Tapia de Daza 1991. At room temperature a good relative humidity sensor can measure a condition of 0950 Aw with an accuracy of 001 Aw or better.
In terms of dew point the equivalent accuracy is 0175C. In both cases this is close to the accuracy available from a good laboratory chilled-mirror instrument. Chilled mirror is the moisture measurement technology of choice for national standards laboratories worldwide.
Chilled mirror has the highest attainable accuracy of any dew-point measurement technology and provides excellent repeatability over a wide measurement range. Sensors for measuring dew point are chilled mirrors metal oxide and polymer sensors. Chilled mirror technology can offer the highest accuracy over a wide range of dew points.
The operating principle is based on the fundamental definition of dew point cooling a volume of air until condensation forms. A gas sample passes over a metallic. The DewTrace is a high precision bench top laboratory standard dewfrost point hygrometer capable of measuring very low frost points using the primary method chilled mirror measurement technique.
It incorporates novel ice nucleation technology to reach low frost points in minutes giving it superior performance over a wide dynamic range from ambient to trace moisture concentration levels. The optical chilled mirror hygrometer which provides a fundamental primary measurement of dew point and the capacitive polymer sensor which provides a non-fundamental secondary measurement of Relative Humidity. The Dew Star S-3 Chilled Mirror System is a high performance Chilled Mirror Sensor with Peltier Thermoelectric mirror cooling to measure high frost points.
It provides accurate and reliable dew point measurement over an extended range for long periods of time with the new ACCU-STAR mirror maintenance feature. The unique dew point tester designed by Stryn refrigeration and chilled mirror measuring principle can make the instrument perform dew point measurement accurately at any ambient temperature and the dull scale measurement accuracy can reach 02 C. Minimum to -110 C dew point 100 ppb no additional cooling module required.
Optical Chilled Mirror Hygrometers. Optidew Optical Dewpoint and RH Transmitter Dewpoint temperature and RH measurement Fundamental method of dewpoint and RH measurement Range-40F to 248F. 045 to 100 RH Accuracy of 027F Single two stage and harsh environment sensor options Dual 4-20mA outputs.
Alarm relay Optidew Optical Dewpoint and RH Transmitter. This method is mainly used for calibration. The chilled mirror dew-point meter measures the dew-point directly.
However when using a modern chilled mirror dew-point hygrometer the small metal mirror in the sample gas stream is cooled by Peltier elements to such a degree that the controlling photo sensors can only just detect dew or ice deposits. All chilled-mirror devices both manual and automatic are based on this same basic method. It is necessary to measure both the condensation and evaporation temperatures because the dew point is actually the equilibrium temperature at which water molecules.
Rugged Michells chilled mirror products are designed to withstand industrial use Fundamental The optical condensation principle of dew point measurement has been established for centuries as the most fundamental method of determining the moisture content of a gas. Chilled Mirror Dew Point Method. ASTM D 6836-02 describes five methods methods AE for measurement of soilwater characteristic curve SWCC.
Chilled mirror hygrometer method is classified as Method D which is generally used to determine the SWCC corresponding to high suctions and low water contents.